How to record or delete meter values with a date before the last one recorded?
Valuekeep allows for recording values in meters in dates before the last recorded system reading. In this case, when registering a reading on a date before the last one recorded, the system automatically recalculates the meter accumulation taking into account the records that come after it. This recalculation is done according to the type of meter. For Reading meters, only the entry immediately after the recorded value is recalculated, while for Increment meters, this is done for all entries after the recorded value.
Valuekeep allows you to remove meter values in any period, always ensuring that the meter’s accumulated value is recalculated for every day affected by the operation. Recalculation follows the same reporting logic, which means it bears the type of meter into account.